FEDERAL PROCESS CO -- GASOILA SOFT SET -- 8040-00-076-2553
===================== Product Identification =====================
Product ID:GASOILA SOFT SET
MSDS Date:07/22/1993
FSC:8040
NIIN:00-076-2553
=== Responsible Party ===
Company Name:FEDERAL PROCESS CO
Address:24400 HIGHPOINT RD
City:CLEVELAND
State:OH
ZIP:44122
Country:US
Info Phone Num:216-464-6440
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:97785
=== Contractor Identification ===
Company Name:FEDERAL PROCESS CO
Address:4620 RICHMOND ROAD
City:CLEVELAND
State:OH
ZIP:44128
Country:US
Phone:216-484-8440
CAGE:97785
============= Composition/Information on Ingredients =============
Ingred Name:ISOPROPYL ALCOHOL (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
Fraction by Wt: 10-15%
OSHA PEL:400 PPM
ACGIH TLV:400 PPM/500 STEL
Ingred Name:ETHANOL, 2-BUTOXY-, ACETATE; (ETHYLENE GLYCOL MONOBUTYL
ETHER ACETATE)
CAS:112-07-2
RTECS #:KJ8925000
Fraction by Wt: 13-18%
OSHA PEL:50 PPM (MFR)
ACGIH TLV:25 PPM (MFR)
Ingred Name:TEFLON (PTFE)
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:NOT APPLICABLE. CHRONIC:ANIMAL
STUDIES HAVE CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON THE
CNS, BLOOD FORMING TISS, BLOOD, KIDNEYS & LIVER ASSOC W/ADMIN OF
ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE). (EXTRACTED FROM DHHS
(NIOSH) PUB NO. 90-118) .
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH WATER FOR @ LEAST 15 MINUTES. SKIN:APPLY SKIN
LOTION, WASH CLOTHING. INHAL:MOVE TO VENTILATED AREA. INGEST:CALL
PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:70.0F,21.1C
Lower Limits:1.1%
Upper Limits:10.6%
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL OR WATER.
Fire Fighting Procedures:NONE. WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:NORMAL GOOD HOUSEKEEPING PROCEDURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AWAY FROM HEAT, CLOSE CONTAINER
AFTER USE. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:SHOULD NOT BE USED WITH OXYGEN. INGREDIENTS IN
GASOILA HAVE A HYDROCARBON BASE & CAN OXIDIZE READILY CAUSING
POSSIBLE EXPLOXSION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AVOID PROLONGED BREATHING OF FUMES-USE IN WELL
VENTILATED AREAS. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NOT APPLICABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER USE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:180F,82C
Vapor Pres:0.88 @ 25C
Vapor Density:1
Spec Gravity:1.41 (H*2O=1)
Evaporation Rate & Reference:0.6 (BUTYL ACETATE =1)
Solubility in Water:SLIGHT
Appearance and Odor:LIGHT BLUE PASTE, SLIGHT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
LIQUID OXYGEN SYSTEMS, LIQUID SODIUM, GASEOUS FLUORINE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:NOT APPLICABLE. DISPOSAL MUST BE IN ACCORDANCE
WITH FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.