CRC INDUSTRIES INC -- LECTRA MOTIVE (AEROSOL), 5018T -- 6850-00N072542
=====================  Product Identification  =====================

Product ID:LECTRA MOTIVE (AEROSOL), 5018T
MSDS Date:05/26/1994
FSC:6850
NIIN:00N072542
=== Responsible Party ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:800-424-9300(CHEMTREC)
Preparer's Name:ADAM SELISKER
CAGE:CRCIN
=== Contractor Identification ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Phone:215-674-4300
CAGE:CRCIN
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2820
Country:US
Phone:215-674-4300/800-424-9300
CAGE:10136

=============  Composition/Information on Ingredients  =============

Ingred Name:METHANE, DICHLORO-; (DICHLOROMETHANE) (SARA 313) (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 1-20%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM, A2
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ETHYLENE, TETRACHLORO-; (TETRACHLOROETHYLENE) (SARA 313)
    (CERCLA)
CAS:127-18-4
RTECS #:KX3850000
Fraction by Wt: 70-100%
OSHA PEL:100 PPM
ACGIH TLV:25PPM/100STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 1-5%
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL

Ingred Name:SUPDAT:NTP 7TH ANNUAL REPORT ON CARCINOGENS,
    1994:ANTICIPATED TO BE CARCINOGEN. ANIMAL:LIVER TUMORS.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:HEADACHES, DIZZINESS,
    ANESTHESIA, UNCONSCIOUSNESS. EYES:CAUSES PAIN AND SOME IRRITATION.
    SKIN:IRRITATION ON REPEATED EXPOSURES. CHLOROCARBON MATLS HAVE
    PRDCED SENSIT OF MYOCARDIUM TO  EPINEPHRINE IN LAB ANIMALS & COULD
    HAVESIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:DICHLOROMETHANE:IARC MONOGRAPHS, SUPP,
    VOL 7, PG 194, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS,
    1994:ANTIC (SUPDAT)
Effects of Overexposure:HLTH HAZS:BE CONTRAINDICATED EXCEPT FOR
    LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO
    CHLOROCARBONS . CHRONIC:REPEATED OVEREXPOSURES HAVE CAUSED LIVER
    AND KIDNEY EFFECTS IN ANIMA LS.
Medical Cond Aggravated by Exposure:RISK TO YOUR HEALTH DEPENDS ON
    DURATION AND LEVEL OF EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:(IF SYMPTOMS PERSIST, CALL A PHYSICIAN). INHALATION:REMOVE TO
    FRESH AIR. APPLY ARTIFICAL RESPIRATION IF NECESSARY. EYES:FLUSH
    WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN:REMOVE
    CONTAMINA TED CLOTHING. WASH AREA WITH SOAP AND WATER. INGESTION:DO
    NOT INDUCE VOMITING. CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA &
    FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOL CONTAINERS MAY EXPLODE WHEN
    HEATED ABOVE 120F. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL
    AND PHOSGENE .

==================  Accidental Release Measures  ==================

Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS. AREA
    SHOULD BE VENTILATED AND AN ABSORBENT USED TO PICK UP EXCESS
    MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY AREA. VAPS ARE
    HVR/AIR. DO NOT USE IN CONFINED SPACE WITHOUT ADEQ VENT. USE NIOSH
    APPROVED BREATHING APPARATUS IF NECESSARY.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
    VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
    UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:ABOVE TLV USE NIOSH APPROVED SELF-CONTAINED
    BREATHING APPARATUS.
Ventilation:MAINTAIN VAPOR CONCENTRATION BELOW THE TLV. USE MECHANICAL
    MEANS IF NECESSARY.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER . NOT NORMALLY REQUIRED WITH AEROSOL PRODUCT USAGE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PHYSICAL DATA (W/OUT PROPELLANT):BP:>250F,>121C; SPEC GRAV:1.60 @ 25C;
    EVAP RATE:RAPID; SOL IN H*2O:SLIGHT SOLUBILITY IN H*2O-GOOD SOLV
    FOR MAY ORG MATLS; % VOLAT:100. EXPLAN OF CARCIN:TO BE CARCIN. A
    NIMAL:LUNGS, THORAX, ENDOCRINE SYS. TETRACHLOROETHYLENE:IARC
    MONOGRAPHS, SUPP, VOL 7, PG 355, 1987:GROUP 2B. (ING 4)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:SUPP DATA
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:SUPP DATA
Solubility in Water:SUPP DATA
Appearance and Odor:W/OUT PROPELLANT:COLORLESS LIQ-IRRITATING ODOR AT
    HIGH CONCS.
Percent Volatiles by Volume:SUPDAT

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND/OR
    ZINC POWDER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL-HYDROGEN CHLORIDE, CHLORINE,
    AND SOME PHOSGENE. AVOID OPEN FLAMES, ARCS OR HIGH TEMPS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
    OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.