COLGATE-PALMOLIVE CO -- 04199, PROFESSIONAL AJAX WINDOW CLEANER/ (S -- 7930-00N030296
=====================  Product Identification  =====================

Product ID:04199, PROFESSIONAL AJAX WINDOW CLEANER/ (S
MSDS Date:07/01/1990
FSC:7930
NIIN:00N030296
=== Responsible Party ===
Company Name:COLGATE-PALMOLIVE CO
Address:101 NORTH SUMMIT ST
City:TENAFLY
State:NJ
ZIP:07670
Country:US
Info Phone Num:201-878-7533
Emergency Phone Num:412-692-5596
CAGE:86223
=== Contractor Identification ===
Company Name:COLGATE-PALMOLIVE CO
Address:300 PARK AVE
Box:City:NEW YORK
State:NY
ZIP:10022-7402
Country:US
Phone:212-310-2000
CAGE:86223

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHANOL, 2-BUTOXY; (BUTYL CELLOSOLVE)
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 3%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM; 9293

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:THIS MIXTURE HAS NOT BEEN TESTED AS A
    WHOLE. INGEST: NAUSEA, VOMITING AND DIARRHEA. EYES: IRRITANT UPON
    DIRECT CONTACT. SKIN: MAY CAUSE IRRITATION UPON PROLONGED CONTACT.
    INHAL: NOT KNOWN. IF YOU BREA THE SOME OF THIS PRODUCT, IT MAY
    CAUSE COUGHING. (SEE EFFECTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ANIMAL STUDIES CLEARLY DEMONSTRATED
    DOSE-RELATED ADVERSE EFFECTS ON CNS, HEMATOPOIETIC TISSUES, BLOOD,
    KIDNEYS & LIVER, ASSOCIATED WITH THE ADMINISTRATION OF ETHYLENE
    GLYCOL MONOBUTYL ETHER  (EGBE). (EXTRACTED FROM DHHS (NIOSH)
    PUBLICATION NO. 90-118) .
Medical Cond Aggravated by Exposure:NOT KNOWN.

=======================  First Aid Measures  =======================

First Aid:INGEST: DRINK SIPS OF WATER OR MILK. IF VOMIT CONTINUES, CALL
    POIS CTR OR MD. EYES: POUR WARM WATER THRU THE EYES FOR AT LEAST 15
    MINUTES. IF EYE STILL BOTHERS YOU, CALL POIS CTR OR MD. SKIN: TAKE
    OFF  WET CLOTHES. POUR WARM WATER ON SKIN FOR AT LEAST 15 MIN. IF
    NOT BETTER, CALL POIS CTR OR MD. INHAL: TAKE SOME SLOW DEEP BREATHS
    OF FRESH AIR & SIP SOME WATER. IF STILL COUGHING, CALL POIS CTR OR
    MD.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:CO2, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SMALL SPILLS CAN BE BRUSHED UP WITH A BROOM OR
    VACUUMED UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL DRY PLACE (40F TO
    125F).
Other Precautions:KEEP OUT OF REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:AVOID CONTACT WITH SKIN AND EYES.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: LIGHT DUTY ALL PURPOSE CLEANER. PH: 10.5 +/-
    0.5.

==================  Physical/Chemical Properties  ==================

HCC:B3
Spec Gravity:0.99 
pH:SUPDAT
Solubility in Water:COMPLETE
Appearance and Odor:BLUE LIQUID, AMMONIA ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT MIX WITH CHLORINE BLEACH OR
    PRODUCTS WHICH CONTAIN CHLORINE.
Hazardous Decomposition Products:NONE KNOWN.

====================  Disposal Considerations  ====================

Waste Disposal Methods:PREFERRED METHOD IS INCINERATION AT A LICENSED
    APPROVED FACILITY. EMPTY CONTAINERS MAY BE DISPOSED AS CONVENTIONAL
    WASTE. DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE, AND
    LOCAL REGULATIONS (FP  N).

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.